DATA-CHL (Data Channel)
Issue 4 May 2002
10-489 555-233-123
Data Channel Reset Test (#107)
This test is destructive.
This test resets the data communications interface that DATA-CHLs provides and
drops all existing connections.
Data Channel Dual Port RAM Test (#108)
This test is destructive.
Hardware and software share the dual port RAM. This test requests each side to
read and write the dual port RAM, first one at a time and then simultaneously in
alternate locations.
This test prevents new connections from establishing over the DATA-CHLs,
however, existing connections are not (and cannot) be dropped.
Table 10-179. TEST #107 Data Channel Reset Test
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT Could not allocate the necessary system resources to run this
test.
1. Try the command at 1-minute intervals, up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run this
test.
10704 ABORT Internal system error
1. Try the command at 1-minute intervals, up to 5 times.
Any FAIL The circuit pack failed to reset.
1. Execute the command again.
2. If the problem persists, replace the Processor circuit pack.
3. Reset Time-of-Day clock (set time).
PASS The circuit pack initializes correctly.