EasyManua.ls Logo

Avaya Definity SI - Page 1278

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Object Repair Procedures
555-233-123
10-492 Issue 4 May 2002
1000 ABORT Error Code of 1000 can mean one of several things:
a. Target DATA-CHL is busy and, therefore, not available for
use.
b. No other DATA-CHLs are administered and, therefore,
not available to place the call to the target DATA-CHL.
c. All other DATA-CHLs are busy and, therefore, not
available to place the call to the target DATA-CHL.
d. Could not allocate the necessary system resources to run
this test.
e. Internal system error.
If the results of Tests #110 and #111 are both PASS, then there
is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to
completely test the target DATA-CHL:
1. Determine if errors exist on links using target DATA-CHL
(status link).
2. If there are no errors, busyout the links (busyout link).
3. Determine if no other DATA-CHLs are administered (list
data-module).
4. If no other DATA-CHLs are administered, administer at least
one.
5. Determine if links exist on all non-target DATA-CHLs (status
link).
6. If links exist on all DATA-CHLs, busyout the links (busyout
link).
7. Retry the command at 1-minute intervals, up to 5 times.
8. Restore any busied out links.
Table 10-181. TEST #109 Data Channel Remote Maintenance Loop Around
Test Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page

Table of Contents

Related product manuals