DATA-CHL (Data Channel)
Issue 4 May 2002
10-493 555-233-123
1006 ABORT For this test, an Error Code of 1006 can have one of several
different meanings:
a. No other DATA-CHLs are administered and, therefore,
not available to place the call to the target DATA-CHL.
b. All other DATA-CHLs are busy and, therefore, not
available to place the call to the target DATA-CHL.
c. Could not allocate the necessary system resources to run
this test.
d. Internal system error.
If the results of Tests #110 and #111 are both PASS, then there
is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to
completely test the target DATA-CHL:
1. Determine if no other DATA-CHLs are administered (list
data-module).
2. If no other DATA-CHLs are administered, administer at least
one.
3. Determine if errors exist on links using target DATA-CHL
(status link).
4. If there are no errors, busyout the links (busyout link).
5. Retry the command at 1-minute intervals, up to 5 times.
6. Restore any busied out links.
1016 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals, up to 5 times.
1018 ABORT Test disabled through software patch.
2003 ABORT Internal system error
2004 ABORT Internal system error
1. Check dial plan to ensure data channel extensions are set up
as local extensions rather than remote or UDP extensions.
2. Retry the command at 1-minute intervals, up to 5 times.
Table 10-181. TEST #109 Data Channel Remote Maintenance Loop Around
Test Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page

Table of Contents