Maintenance Object Repair Procedures
555-233-123
10-496 Issue 4 May 2002
Tests #107, #108, and #111 on the DATA-CHL can be helpful to determine which
DATA-CHL is defective.
NOTE:
If Error Code recommend busying out a CDR, System Printer, Journal
Printer, or PMS Link, restore each busied out link to service before
concluding work on the problem.
Table 10-182. TEST #110 Data Channel Crosstalk Test
Error
Code
Te s t
Result Description/Recommendation
4 ABORT Error Code 4 can mean 1 of 2 problems:
d. Target DATA-CHL is busy and, therefore, not available for
use.
e. Internal system error.
If the results of Tests #110 and #111 are both PASS, then there is
a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to
completely test the target DATA-CHL:
1. Determine if errors exist on links using target DATA-CHL
(status link).
2. If there are no errors, busyout the links (busyout link).
3. Retry the command at 1-minute intervals, up to 5 times.
4. Restore any busied out links.
40
70
75
ABORT Internal system error
1. Retry the command at 1-minute intervals, up to 5 times.
Continued on next page