DATA-CHL (Data Channel)
Issue 4 May 2002
10-497 555-233-123
1000 ABORT Error Code of 1000 can mean one of several things:
a. The target DATA-CHL is busy and, therefore, not available
for use.
b. Could not allocate the necessary system resources to run
this test.
c. Internal system error
If the results of Tests #110 and #111 are both PASS, then there is
a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to
completely test the target DATA-CHL:
1. Determine if errors exist on links using target DATA-CHL
(status link).
2. If there are no errors, busyout the links (busyout link).
3. Determine if no other DATA-CHLs are administered (list
data-module).
4. If no other DATA-CHLs are administered, administer at least
one.
5. Determine if links exist on all non-target DATA-CHLs (status
link).
6. If links exist on all DATA-CHLs, busyout the links (busyout
link).
7. Retry the command at 1-minute intervals, up to 5 times.
8. Restore any busied out links.
1002 ABORT Error Code 1002 can mean 1 of 2 problems:
a. Could not allocate the necessary system resources to run
this test.
b. Internal system error.
1006 ABORT Could not allocate the necessary system resources to run this test.
1016 ABORT Resources for the test are not available.
1. Retry the command at 1-minute intervals, up to 5 times.
1018 ABORT Test disabled through software patch.
2000 ABORT Could not allocate the necessary system resources to run this test.
2003 ABORT Internal system error
1. Retry the command at 1-minute intervals, up to 5 times.
Table 10-182. TEST #110 Data Channel Crosstalk Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page