DID-DS1 (DS1 DID Trunk)
Issue 4 May 2002
10-521 555-233-123
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57476, on-hook before wink; 57477, on-hook
before ready to receive digits; 57485, wink too short for valid signal.
Escalate the error.
Table 10-192. DID-DS1 Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test trunk <grp>/<mbr> sh r 1
1 (a) Any
15 (b) Any Port Audit and
Update Test (#36)
18 (c) WARNING OFF release trunk <grp>/mbr>
130 (d) None WARNING ON test trunk <grp>/<mbr>
257 (e) 57474
57473
513 (f) 57392 None MIN/MAJ
2
2 This alarm will only be raised when the System-Parameter Country form has the Base Tone
Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this
trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm.
OFF
769 (g) 57393 None MIN/MAJ
2
OFF
1281 Conference Circuit
Test (#7)
MAJ/MIN/
WRN
3
3 Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command. If the Minor alarm is not downgraded by the set options values, the Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
ON test trunk <grp>/<mbr> l
1537 NPE Crosstalk Test
(#6)
MAJ/MIN/
WRN
3
ON test trunk <grp>/<mbr> l
1793
(h)
ON test board PCSS l
2305(i) 50944 None MIN/MAJ
2
OFF
3840
(j)
Port Audit and
Update Test (#36)
Continued on next page