Maintenance Object Repair Procedures
555-233-123
10-548 Issue 4 May 2002
61472 FAIL Battery feed test failed. A problem with the incoming CO-line
was detected.
1. Check the incoming CO-line for proper operation. If
warranted, refer the problem to the CO.
2. If the CO-line checks out OK, the failure must be on the
DID port. Replace the circuit pack.
PASS Current flow was detected for this port.
1. User-reported troubles on this port should be investigated
using other port tests and by examining connections.
2. Refer problem to the CO.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct.
Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish
the linkage between the internal ID and the port.
Table 10-199. TEST #35 Port Diagnostic Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page