DID-TRK (DID Trunk)
Issue 4 May 2002
10-549 555-233-123
Port Audit Update Test (#36)
This test sends updates of the DID port translation for all ports on the circuit pack
that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data includes: wink or immediate start trunk, dial tone or
rotary dialing trunk, rotary dialing inter-digit timing, Network balance R/RC, and
disconnect timing.
Table 10-200. TEST #36 Port Audit Update Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1006 ABORT The port has been placed out of service, perhaps by craft
busyout. Use the display port PCSSpp command to
determine the trunk group/member number of the port. Use
the status trunk command to determine the service state of
the port. If the service state indicates that the port is out of
service, then the port is unavailable for certain tests. You must
wait until the port is in service and idle before retesting.
1. If the port status is in service and idle, then retry the
command at 1-minute intervals for a maximum of 5 times.
Continued on next page