Table 10-218. TEST #6 NPE Crosstalk Test
Error
Code
Te s t
Result Description/Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available.
The port may be in use on a valid call. Use the status station
or status trunk command to determine when the port is
available for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1001 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. The status
health command can be used to determine if the system is
experiencing heavy traffic. Refer to the TDM-BUS (TDM Bus)
Maintenance documentation to diagnose any active TDM-BUS
errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some tone detectors may be out-of-service. The list
measurements tone-receiver command will display
information on the system’s tone receivers.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
Continued on next page