1004 ABORT The port has been seized by a user for a valid call. Use the
status trunk command to determine when the port is available
for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1020 ABORT The test did not run due to a previously existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or
the circuit pack and attempt to diagnose the already
existing error.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2053 ABORT At least one of the following errors is found on the DS1 circuit
pack:
1281Loss of signal
1793Blue Alarm
2049Red Alarm
2305Yellow Alarm
1537Hyperactivity
Look for the above error types in the Hardware Error Log and
follow the procedures given in the appropriate DS1-BD or
UDS1-BD maintenance documentation for the listed error
types.
FAIL The NPE of the tested port was found to be transmitting in
error. This will cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
User-reported troubles on this port should be investigated
using other port tests and examining station, trunk, or external
wiring.
Table 10-218. TEST #6 NPE Crosstalk Test Continued
Error
Code
Te s t
Result Description/Recommendation