Maintenance Object Repair Procedures
555-233-123
10-594 Issue 4 May 2002
Table 10-221. TEST #314 DS1 CO Dial Tone Seizure Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available.
The port may be in use on a valid call. Use the status trunk
command to determine when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use the
status trunk command to determine when the port is available
for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1005 ABORT Test failed due to incompatible configuration administered in
trunk group form.
1. Look at the trunk group administration form and see
whether the trunk is incoming only, port 24 on a DS1
Interface with common control channel signaling, or an
automatic CO type such as FX. Under any of these
conditions this is a normal abort.
1018 ABORT Test has been disabled via administration.
1. Verify that the ‘‘Maintenance Tests’’ field on the Trunk
Group Form is set to ‘‘n.’’ To enable the test, issue the
change trunk-group x command where ‘‘x’’ equals the
number of the trunk group to be tested. Then change the
entry in the ‘‘Maintenance Tests’’ field on the form to ‘‘y.’’
2. Repeat the test.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for UDS1-BD errors in the Hardware Error Log. If
present, refer to the UDS1-BD (DS1/UDS1 Trunk Circuit
Pack) Maintenance documentation.
2. Retry the command.
Continued on next page