DIOD-DS1 (DS1 DIOD Trunk)
Issue 4 May 2002
10-595555-233-123
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit
pack:
1281Loss of signal
1793Blue Alarm
2049Red Alarm
2305Yellow Alarm
1537Hyperactivity
Look for the above error types in the Hardware Error Log and
follow the procedures given in the appropriate DS1-BD or
UDS1-BD maintenance documentation for the listed error
types.
FAIL The trunk cannot be seized for an outgoing call.
1. Verify that the Trunk Type field on the trunk administration
screen form matches the trunk type administered on far
end switch.
2. Look for UDS1-BD errors in Hardware Error Log. If
present, refer to the UDS1-BD (DS1/UDS1 Trunk Circuit
Pack) Maintenance documentation.
3. Retry the test at 1-minute intervals for a maximum of 5
times.
PASS The trunk can be seized for an outgoing call.
Table 10-221. TEST #314 DS1 CO Dial Tone Seizure Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page

Table of Contents