Maintenance Object Repair Procedures
555-233-123
10-698 Issue 4 May 2002
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Tone Detection
Verification Test, for example, you may also clear errors generated from other
tests in the testing sequence.
Tone Detection Verification Test (#42)
This test verifies the “touch-tone digits detection” capability of the DTMR port is
functioning properly.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive; ND = Nondestructive
Tone Detection Verification Test (#42) X X ND
Tone Detector Audit/Update Test (#43) X X ND
Table 10-253. TEST #42 Tone Detection Verification Test
Error
Code
Te s t
Result Description/Recommendation
none ABORT The system was not able to allocate all the resources needed
for this test or there was an Internal System Error.
1 ABORT The system could not allocate all the resources needed to test
the DTMR port.
1001 ABORT The system was unable to put the DTMR port in the
appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test
connection. This could happen when the system is heavily
loaded. If the system is not heavily loaded, then test the TDM
Bus via the test tdm [a|b] command. Refer to the TDM-BUS
(TDM Bus) Maintenance documentation for details.
1. Retry the command at one-minute intervals a maximum of
5 times.
Continued on next page