DTMR-PT [Dual Tone Multifrequency Port (TTR)]
Issue 4 May 2002
10-699555-233-123
1003 ABORT The system could not allocate a Tone Generator for the test
connection. This could happen when the system is heavily
loaded or there is not a Tone-Clock circuit pack in the port
network when this test is being executed.
1. Make sure there is a Tone-Clock circuit pack in the same
port network.
2. If a Tone-Clock circuit pack is missing, install one in the
same port network.
3. Allow about one-minute for the Tone-Clock maintenance
to run on the newly inserted Tone-Clock circuit pack.
4. Retry the command at one-minute intervals a maximum of
5 times.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
5 times.
2006 ABORT DTMF detection failed. This could be caused by the
administered companding mode of the system not matching
that of the Tone Detector circuit pack.
1. Make sure that companding mode of the system matches
that of the Tone Detector.
1-3 FAIL DTMF digits were not correctly detected.
1. Run the Short Test Sequence: test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In order to
restore the system performance to normal, replace the
Tone Detector circuit pack containing the defective DTMR
port.
PASS The DTMR port is able to detect all the touch-tone digits.
Table 10-253. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page