Maintenance Object Repair Procedures
555-233-123
10-700 Issue 4 May 2002
Tone Detector Audit/Update Test (#43)
The DTMR port is refreshed with all time slot information and sanity audit is
performed on the DTMR port.
Table 10-254. TEST #43 Tone Detector Audit/Update Test
Error
Code
Te s t
Result Description/Recommendation
ABORT The system was not able to allocate all the resources needed
for this test.
1. Wait one minute and try again.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals for a
maximum of 5 times.
FAIL Hardware audit failed.
1. Run the Short Test Sequence: test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating
properly but system capacity is reduced. In order to
restore the system performance to normal, replace the
Tone Detector circuit pack containing the defective DTMR
port.
PASS The DTMR port has been successfully refreshed with its
translation.