Loading...
EXT-DEV ADMIN? N (External Device Alarm)
Issue 4 May 2002
10-819555-233-123
Notes:
a. Refer to POWER (Battery & Battery Charger) section for a description of
this test.
b. Refer to AC-POWER (AC Power) section for a description of this test.
c. Refer to CARR-POW (Carrier Port Power Supply) section for a description
of this test.
d. Refer to EMG-XFER (Emergency Transfer) section for a description of this
test.
e. Refer to CABINET (Cabinet Sensors) section for a description of this test.
f. Refer to RING-GEN (Analog Ring Generator) section for a description of
this test.
Notes:
a. Refer to DC-POWER (Single Carrier Cabinet Power) section for a
description of this test.
b. Refer to EMG-XFER (Emergency Transfer) section for a description of this
test.
c. Refer to RING-GEN (Analog Ring Generator) section for a description of
this test.
Single Carrier Cabinet Tests
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive; ND = Nondestructive
SCC Power Query Test (#79) (a) X X ND
Emergency Transfer Query Test (#124) (b) X X ND
External Device Alarm Test (MAJOR port) (#120) X X ND
External Device Alarm Test (MINOR port) (#120) X X ND
Analog Ring Generator Initialization Test (#117) (c) X X ND
Analog Ring Generator Query Test (#118) (c) X X ND

Table of Contents

Related product manuals