FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-833555-233-123
17 FAIL The translations and announcements are different in both
SPEs. The Active SPE has the most current translations
and the Standby SPE has the most current
announcements.
18 FAIL The translations and announcements are different in both
SPEs. The standby SPE is the most current.
1. Follow the procedures for Error Code 9.
20 FAIL The load vintages and announcements are different in both
SPEs. The Standby SPE has the most current
announcements.
21 FAIL The translations, announcements, and load vintages are
different in both SPEs. The Active SPE has the most
current translations and the Standby SPE has the most
current announcements.
22 FAIL The translations, announcements, and load vintages are
different in both SPEs. The Standby SPE has the most
current translations and announcements.
1. Follow the procedures for Error Code 4. Be sure to
issue the save announcements command.
32 FAIL The update files are different in both SPEs. The update file
on the Active SPE is most current.
1. Have INADS issue the copy update-file command. If
the update file copy passes, go to Step 2.
2. Reissue test card-mem long to resolve the alarms.
33 FAIL The update files and translations are different in both
SPEs. The Active SPE has the most current update file and
translations.
34 FAIL The update files and translations are different in both
SPEs. The Active SPE has the most current update file,
and the Standby SPE has the most current translations.
1. Issue the save translations command to save
translations on both SPEs.
2. Have INADS issue the copy update-file command to
copy the update file from the Active to the Standby
SPE.
3. Reissue test card-mem long to resolve the alarms.
36 FAIL The update files and load vintages are different in both
SPEs. The Active SPE has the most current update file.
Table 10-303. TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Te s t
Result Description/Recommendation
Continued on next page