Maintenance Object Repair Procedures
555-233-123
10-840 Issue 4 May 2002
164 FAIL The load vintages and the update files are different in both
SPEs, and the translation memory card in the Active SPE
is missing. The update file in the Active SPE is more
current.
1. Both load vintages and update files should not be
mismatched.
192 FAIL The update file in the Standby SPE is more current and the
translation memory card is missing in the Active SPE.
1. Follow the procedures for Error Code 160.
196 FAIL The load vintages and the update files are different in both
SPEs, and the translation memory card in the Active SPE
is missing. The update file in the Standby SPE is more
current.
1. Follow the procedures for Error Code 164.
256 ABORT Translation memory card is missing in the Standby SPE.
260 FAIL The load vintages are different in both SPEs and the
translation memory card is missing in the Standby SPE.
1. Follow the procedures for Error Code 132.
288 FAIL The update file in the Active SPE is more current and the
translation memory card is missing in the Standby SPE.
1. Follow the procedures for Error Code 160.
292 FAIL The load vintages and the update files are different in both
SPEs, and the translation memory card is missing in the
Standby SPE. The update file in the Active SPE is more
current.
1. Follow the procedures for Error Code 164.
320 FAIL The update file in the Standby SPE is more current and the
translation memory card is missing in the Standby SPE.
1. Follow the procedures for Error Code 160.
324 FAIL The load vintages and the update files are different in both
SPEs and the translation memory card in the Standby SPE
is missing.
1. Follow the procedures for Error Code 164.
Table 10-303. TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Te s t
Result Description/Recommendation
Continued on next page