FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-839555-233-123
85 FAIL The update files, load vintages, translations, and
announcements are different in both SPEs. The Active
SPE has the most current translations, and the Standby
SPE has the most current update file and announcements.
86 FAIL The update files, load vintages, translations, and
announcements are different in both SPEs. The Standby
SPE has the most current update file, translations, and
announcements.
1. Follow the procedures for Error Code 4 to correct the
load vintage. After running test card-mem long,
check for Error Codes 32 or 64. Follow the recovery
procedure under the applicable error code.
128 ABORT The Translation memory card in the Active SPE is missing.
132 FAIL The load vintages are different in both SPEs and the
translation memory card is missing in the Active SPE.
1. Follow the procedures for Error Code 4 to correct the
software vintage.
2. Insert the translation memory card in the Active SPE.
3. Run test card-mem long again to resolve alarms.
160 FAIL The update file in the Active SPE is more current than the
Standby SPE and the translation memory card is missing
in the Active SPE.
1. Have INADS issue copy update-file. If the update file
copy passes, proceed to Step 2.
2. Insert the translation memory card in the Active SPE.
3. Reissue test card-mem long to resolve the alarms.
Table 10-303. TEST #421 Flash Data Consistency Check Test Continued
Error Code
Te s t
Result Description/Recommendation
Continued on next page