Loading...
Maintenance Object Repair Procedures
555-233-123
10-900 Issue 4 May 2002
PASS Hybrid Circuit and Conference Circuit Test passed. The hybrid
circuitry is transmitting properly.
1. If complaints still exist, investigate by using other port
tests, and by examining the station, wiring, and
connections.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use the list config command, and resolve any problems
that are found.
2. If the board was found to be correctly inserted in step 1,
issue busyout board.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue test board long. This should re-establish the
linkage between the internal ID and the port. If this is not
the case, dispatch to check to ensure that there is a valid
board inserted.
Table 10-326. TEST #57 Hybrid Circuit and Conference Circuit Test Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page

Table of Contents