EasyManua.ls Logo

Avaya Definity SI - Page 1783

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ISDN-TRK (DS1 ISDN Trunk)
Issue 4 May 2002
10-997555-233-123
ISDN Test Call Test (#258)
This test performs a far-end loop around to a far-end switch over an ISDN trunk.
The trunks service state must be in-service, maint-NE, or out-of-service/NE, and
no call can be active on the trunk. The test call can be initiated as part of a long
test sequence, or as an individual test, as described below. This test is valid only
for systems using country protocol 1 (including US), or when the far end has
loop-around capability.
A test call connection is established to a far-end switch over the ISDN trunk to be
tested. The digital port on a TN711D Maintenance/Test circuit pack generates a
test-pattern bit stream which is sent to the far-end switch and echoed back. The
received pattern is then compared to the sent pattern and checked for errors that
indicate a loss of integrity on the communications path.
If a test call is running when scheduled maintenance starts, the green LED is
turned off. To determine if a test call is still running, use the list isdn-testcall and
status isdn-testcall commands. A lit yellow LED on the Maintenance/Test circuit
pack also indicates that a test call is running.
There are two methods available to place an outgoing ISDN-PRI test call in
G3iV1.1-286 and G3iV2-386.
In the first method, the test call connection is established over the TDM Bus of the
transmit and receive sides of the ISDN-PRI trunk to a data channel. This method
is selected when no Maintenance/Test circuit pack resides in the system.
In the second method, the test call connection is established over the TDM Bus of
the transmit and receive sides of the ISDN-PRI trunk to a digital trunk testing port
on the Maintenance/Test circuit pack. The Maintenance/Test Digital Port
generates a pseudo bit stream. A pictorial description of the outgoing ISDN-PRI
test call connectivity is contained in the following figure.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS This switch sent a call state auditing message to the far-end
switch to verify the state of the call active on this trunk. If a call
state mismatch is found, then the call will be torn down within
two minutes. If no call was active, then no message was sent.
Table 10-362. TEST #257 Call State Audit Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page