EasyManua.ls Logo

Avaya Definity SI - Page 1784

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Object Repair Procedures
555-233-123
10-998 Issue 4 May 2002
Figure 10-60. ISDN-PRI Outgoing Test Call
Synchronous Commands
You can demand a synchronous outgoing test call by using the following
maintenance commands:
test trunk trunk-group-no/member-no long [repeat number]
test board board-location long [repeat number]
test port port-location long [repeat number]
Whenever a circuit translates to an ISDN-PRI trunk during a Long Test Sequence,
an outgoing test call is invoked. If the B-channel is unrestricted (B8ZS or HDB3)
the default duration of the test call is 8.6 seconds. Otherwise, if the B-channel is
restricted (ZCS) the default duration of the test call is 9.4 seconds. Once the test
call completes, the bit error rate is retrieved from the Maintenance/Test Digital
Port. A bit error rate greater than zero is reported as a failure to the Manager I
terminal (MGRI). A failure indicates the need to run further diagnostics, such as
the test isdn-testcall command.
If no Maintenance/Test circuit pack exists, the outgoing ISDN-PRI test call is
established over a high speed data channel on the Network Control (NETCON)
circuit pack (DATA-BD).
PI (TN765)
or
PACCON
(TN778)
NETCON SPE
D-channel Setup
B-channel
B-channel
TDM BUS
M/T
TN7771B
DS1/UDS1

Table of Contents