Routine Maintenance Procedures
555-233-123
5-76 Issue 4 May 2002
Screen 5-10. Screen output for status pnc command
3. Enter either list configuration UUC (for the carrier in which the ATM-EI
packs reside) or display circuit-packs cabinet (non-control cabinet) at
the DEFINITY SAT. This command tells you in more detail what boards are
in which slots in each cabinet and carrier. Verify that the TN230Xs are
physically located in the slots indicated on the display.
■ Screen 5-11 on page 5-77 shows the output for display
circuit-packs 1.
■ Screen 5-12 on page 5-77 shows the output for display
circuit-packs 2.
status pnc
PORT NETWORK CONNECTIVITY
Duplicated? no
Software Locked?
Standby Busied?
Standby Refreshed?
Interchange Disabled?
A-PNC B-PNC
Mode: active Mode:
State of Health: State of Health:
Inter PN Index: Inter PN Index:
Major Alarms: 0 Major Alarms:
Minor Alarms: 0 Minor Alarms:
Warning Alarms: 0 Warning Alarms: