MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 4 May 2002
10-1059555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate tests in the order they are presented in Table 10-384. By clearing error
codes associated with the NPE Connection Audit Test, for example, you may also
clear errors generated from other tests in the testing sequence.
Table 10-384. System Technician-Demanded Tests
Order of Investigation
Apply to
TN802?
1
1 N = No; this test either passes or ABORTS with Error Code 2000 (problem with NT)
Short
Tes t
Sequence
Long Test
Sequence
Reset
Board
Sequence D/ND
2
2 D = Destructive; ND = Nondestructive
NPE Connection Audit Test (#50) Y X ND
Control Channel Loop Test (#52) Y X ND
Loss of Signal Alarm Inquiry Test
(#138)
NXX ND
Blue Alarm Inquiry Test (#139) N X X ND
Red Alarm Inquiry Test (#140) N X X ND
Yellow Alarm Inquiry Test (#141) N X X ND
Major Alarm Inquiry Test (#142) N X X ND
Minor Alarm Inquiry Test (#143) N X X ND
Slip Alarm Inquiry Test (#144) N X X ND
Misframe Alarm Inquiry Test (#145) N X X ND
Translation Update Test (#146) N X X ND
SAKI Sanity Test (#53) Y X D
Continued on next page