Maintenance Object Repair Procedures
555-233-123
10-1064 Issue 4 May 2002
Blue Alarm Inquiry Test (#139)
This test is meaningless for the TN802 MAPD circuit pack. Table 10-389 details
the test results.
Red Alarm Inquiry Test (#140)
This test is meaningless for the TN802 MAPD circuit pack. Table 10-390 details
the test results.
Yellow Alarm Inquiry Test (#141)
This test is meaningless for the TN802 MAPD circuit pack. Table 10-391 details
the test results.
Table 10-389. Blue Alarm Inquiry Test (#139) results
Windows NT up
on the TN802? Then Cause
Y Test passes
Y Test aborts with ABORT
2000 Error Code.
Windows NT is not communicating
with the angel firmware.
N Test aborts with ABORT
2000 Error Code.
Windows NT down.
Table 10-390. Red Alarm Inquiry Test (#140) results
If Windows NT is
up on the TN802 When the switch confirms Red alarm:
Y Test passes
N Test aborts with ABORT 2000 Error Code.
Table 10-391. Yellow Alarm Inquiry Test (#141) results
If Windows NT is up
on the TN802 When the switch confirms Yellow alarm:
Y Test passes
N Test aborts with ABORT 2000 Error Code.

Table of Contents