Maintenance Object Repair Procedures
555-233-123
10-1066 Issue 4 May 2002
Misframe Alarm Inquiry Test (#145)
This test is meaningless for the TN802 MAPD circuit pack. Table 10-395 details
the test results.
NOTE:
The query for misframes always returns a 0 count.
Translation Update Test (#146)
The Translation Update Test sends the circuit-pack-level information to the MAPD
Interface circuit pack. Translation includes the following data administered for a
MAPD Interface circuit pack (report from display ds1 UUCSS command):
■ DS1 Link Length between two DS1 endpoints
■ Synchronization Source Control
■ All Zero Suppression
■ Framing Mode
■ Signaling Mode
■ Time Slot Number of the 697-Hz tone
■ Time Slot Number of the 700-Hz tone
Table 10-395. Misframe Alarm Inquiry Test (#145) results
If Windows NT is up
on the TN802 When the switch confirms Misframe alarm:
Y Test passes
N Test aborts with ABORT 2000 Error Code.
Table 10-396. TEST #146 Translation Update Test
Error
Code
Tes t
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute interval s a maximum of 5
times.
FAIL Internal system software error.
1. Verify the MAPD Interface circuit pack translation (display
ds1 UUCSS).
Continued on next page