MEDPRO (Media Processor MAPD Circuit Pack)
Issue 4 May 2002
10-1071555-233-123
4. Be physically inserted into the correct slot
If the circuit pack has an entry in the circuit pack form and either of the
other two conditions are not met, a MINOR alarm is logged. To resolve the
error either
1. Make sure all conditions for administration are met and that a
functioning MedPro circuit pack is inserted in the correct slot
OR
2. Completely remove the MedPro from the system using the following
steps:
a. Remove the administered
IP-Interface associated with the
circuit pack.
b. Physically remove the circuit pack from the slot.
c. Execute the remove medpro UUCSS and change circuit
pack UUCSS commands.
b. Error Type 18 -The MedPro Interface circuit pack has been busied out by
a busyout board UUCSS command.
1. Release the circuit pack (release board UUCSS).
c. Error Type 23 -The MedPro circuit pack is not completely administered. To
be fully administered, a MedPro circuit pack must meet all of these 4
conditions:
1. Have an entry in the circuit plan (change circuit pack)
2. Have the MedPro IP address administered (change node-names)
3. Be enabled (change ip-interface)
4. Be physically inserted into the correct slot.
A DS1 (MEDPRO, MAPD, UDS1-BD and DS1-BD) differs from most circuit
packs in that inserting the circuit pack into the switch is not enough to make
the board usable. It must also be administered.
d. Error Type 125 - no Aux Data: The wrong circuit pack is inserted in the slot
where this circuit pack is logically administered.
1. Remove the wrong circuit pack and insert the logically administered
circuit pack
OR
2. Re-administer this slot to match the circuit pack inserted (change
circuit-pack).
e. Error Type 257 - is associated with the Common Port Circuit Pack
Maintenance Test. Refer to XXX-BD (Common Port Circuit Pack)
Maintenance documentation for details.