Loading...
MEDPRO (Media Processor MAPD Circuit Pack)
Issue 4 May 2002
10-1079555-233-123
Table 10-403. TEST #1381 NT Reset Test
Error
Code
Tes t
Result Description/Recommendation
None ABORT System resources required for this test are not available.
1. Retry the reset board UUCSS command at 1-minute
intervals a maximum of 5 times.
1015 ABORT Port is not out-of-service.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the reset board UUCSS command again.
2100 ABORT System resources required for this test are not available.
1. Retry the reset board UUCSS command at 1-minute
intervals a maximum of 5 times.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute the reset board UUCSS command again.
2. If the problem persists, replace the circuit pack.
PASS The circuit pack initializes correctly.
1. Run the Short Test Sequence.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct.
Administer the MEDPROMEDPRO interface if it is not
already administered.
2. If the board was already administered correctly, check
the error log to determine whether the board is
hyperactive. If this is the case, the board is shut down.
Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step
1, then issue the busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and
the port.