Maintenance Object Repair Procedures
555-233-123
10-1088 Issue 4 May 2002
FAIL Unable to get status for this port. Verify that this board has been
administered correctly, and that there are no alarms against this
board.
PASS The board is functioning properly and the port is in-service and
available.
0NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board
(Error 131) issues, if applicable.
2. Check that the board is properly translated and
inserted. If so, check for hyperactivity (Error 1538). If
hyperactive, use the reset board UUCSS command.
3. Run the test again. If it fails, replace the board and
retest.
Table 10-409. port Status Query Test (#1407) — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page