M/T-ANL (Maintenance/Test Analog Port)
Issue 4 May 2002
10-1139555-233-123
Table 10-429. TEST #13 Analog Port Digital Loop Around Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 3 times.
1000 ABORT The port is in use on a valid ATMS Test Call.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2. If the test continues to abort and the port is not in use
on a valid ATMS Test Call, escalate the problem. To
determine whether the port is in use by an ATMS Test
Call enter status station ext where ext is the assigned
ATMS station number.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to TDM-BUS Maintenance to diagnose any active
TDM-BUS errors. A system is considered under heavy
traffic when the Call Processing Occupancy is greater than
50% or when the System Management and the Call
Processing Occupancies together exceed 65%. To view the
system occupancy measurements enter the command
status system health on the system technician terminal.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic, repeat the test at 1-minute
intervals a maximum of 3 times.
1003 ABORT The system could not allocate a tone receiver for the test.
The system may be oversized for the number of tone
detectors present, or some tone detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the command at
1-minute intervals a maximum of 3 times.