1004 ABORT The port was seized by a valid ATMS Test Call.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2. If the test continues to abort and the port is not in use
on a valid ATMS Test Call, escalate the problem. To
determine whether the port is in use by an ATMS Test
Call enter status station ext where ext is the assigned
ATMS station number.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
7 FAIL Conference test failed on the primary information channel.
1. Run the circuit pack tests to check the Tone/Clock
(TONE-BD) circuit pack and the Tone Detector circuit
pack via the test board PCSS command.
2. Resolve any problems that are detected on the
Tone/Clock (TONE-BD) circuit pack or Tone Detector
circuit pack. See the section on Tone Generator circuit
pack.
3. If the Tone/Clock and Tone Detector circuit packs are
functioning properly, and the test still fails, replace the
Maintenance/Test circuit pack.
14 FAIL The primary information channel is not transmitting
properly. User may not notice any interruption in service or
may not be able to use this port.
1. Run the circuit pack tests to check the Tone Generator
circuit pack and the Tone Detector circuit pack using
test board PCSS.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit pack.
See the section on Tone Generator circuit pack.
3. If the Tone Generator and Tone Detector circuit packs
are functioning properly, and the test still fails, replace
the Maintenance/Test Circuit Pack.
PASS The Maintenance/Test Analog Port analog trunk testing
capability is operating correctly.
Table 10-429. TEST #13 Analog Port Digital Loop Around Test Continued