Maintenance Object Repair Procedures
555-233-123
10-1142 Issue 4 May 2002
Table 10-431. TEST #566 Hook State Inquiry
Error
Code Test Result Description/Recommendation
1 ABORT Switch hook audit timed out. No response was received
from the circuit pack for information about the switch
hook state.
1. Retry the command at 1-minute intervals a
maximum of 3 times.
2. If the test continues to abort, replace the circuit pack
and repeat the test.
2100 ABORT System resources required to run this test are not
available.
1. Retry the command at 1-minute intervals a
maximum of 3 times.
Any FAIL Internal System Error
1. Retry the command at 1-minute intervals a
maximum of 3 times.
2. If the test continues to fail reset the circuit pack via
the busyout board PCSS, reset board PCSS,
release board PCSS command sequence.
3. Retry the command at 1-minute intervals a
maximum of 3 times.
PASS Call processing and Maintenance/Test Analog Port
maintenance software agree on the Maintenance/Test
Analog Port hook state.
Continued on next page