M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286,
G3iV2-386]
Issue 4 May 2002
10-1151555-233-123
Only one value (Pass, Fail, or Abort) is generated as a result of the two tests. If
either fails or aborts, the sequence is stopped.
Table 10-434. TEST #13 Digital Port Loop Around Test
Error
Code
Tes t
Result Description/Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of 5 times.
1000 ABORT The port is in use on a valid ISDN-PRI Test Call. Use list
isdn-testcall to determine which call is using the port (from
the M/T Port column). Either wait for the test call to
complete (as indicated in the Start Time and Duration fields
in the above display), or abort the test call with clear
isdn-testcall tg/mem, where tg/mem is determined from
the B-channel field of the above display.
1. Retry the command at one-minute intervals a
maximum of 5 times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1001 ABORT System resources required to run this test are not
available.
1. Retry the command at one-minute intervals a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to TDM-BUS Maintenance to diagnose any active
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic, repeat the test at one-minute
intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test.
The system may be oversized for the number of tone
detectors present, or some tone detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the command at
one-minute intervals a maximum of 5 times.
Continued on next page