Table 10-444. TEST #312 DS1OPS Switchhook Inquiry Test
Error
Code
Tes t
Result Description/Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of 5
times.
1004 ABORT The port has been seized by a user for a valid call. Use the
status station command to determine when the port is available
for testing.
1. Retry the command at one-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1005 ABORT Test failed due to incompatible configuration administered in
station administration.
1. Verify the station administration is the station assigned to
Port 24 of the DS1 Interface circuit pack while common
channel signaling is specified.
1006 ABORT The test was aborted because the station is out of service. This
condition may be accompanied by an error type 18 entry in the
error log. You may want to determine why the station was taken
out of service. (When stations are taken out of service by
maintenance software, the problems that led up to that must be
cleared.)
1. Use the status station command to check the state of the
port. If the port is indeed out of service, enter the release
station command to bring the station back into service.
2. Retry the command at 1-minute intervals a maximum of 5
times.
3. If the test continues to abort, and the station is in the
in-service/idle state, escalate the problem.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in Hardware Error Log. If present,
refer to the DS1-BD (DS1 Interface Circuit Pack)
Maintenance documentation.
2. Retry the command.
Continued on next page