OPS-LINE (DS1 OPS Line)
Issue 4 May 2002
10-1181555-233-123
1 FAIL Internal System Error.
1. Look for DS1-BD errors in the Hardware Error Log. If
present, refer to the DS1-BD (DS1 Interface Circuit Pack)
Maintenance documentation.
2. If a channel multiplexer is used as the remote DS1 endpoint
to which the station connects, refer to the multiplexer
vendor’s maintenance document for diagnosis.
3. Retry the command at one-minute intervals a maximum of 5
times.
PASS The station hook states in both switch software and DS1
Interface circuit pack are consistent.
0
2012
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use
the list config command, and resolve any problems that are
found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the port.
If this is not the case, dispatch to check to ensure that there
is a valid board inserted.
Table 10-444. TEST #312 DS1OPS Switchhook Inquiry Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page