PDMODULE, TDMODULE (Data Module)
Issue 4 May 2002
10-1193555-233-123
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM Bus) Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling
heavy traffic, repeat the test at one-minute intervals a
maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the command at
one-minute intervals for a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test
has been aborted. Use the display port PCSSpp command
to determine the data module extension. Then use status
data module command with the extension number to
determine the service state of the data module. If the service
state indicates that the data module is in use, then the port is
unavailable for certain tests. You must wait until the port is
idle before retesting.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at one-minute intervals a maximum
of 5 times.
2001 ABORT System resources required to run this test are not available.
1. Retry the test at one-minute intervals a maximum of 5
times.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Rerun the test at one-minute intervals a maximum of 5
times.