Maintenance Object Repair Procedures
555-233-123
10-1194 Issue 4 May 2002
2500 ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
15 FAIL The control channel between the processor and Digital Line
circuit pack is not transmitting properly. This can cause a wide
range of effects. The user may notice nothing or the port may
be totally unusable. This could also disrupt other users.
1. Run circuit pack tests to check the Tone Generator and
the Tone Detector circuit packs using the test board
UUCSS short command.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are
functioning properly, and the test still fails, replace the
Digital Line circuit pack.
Table 10-446. TEST #13 Information and Control Channel Local Loop Test Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page