PI-LINK (Processor Interface Link)
Issue 4 May 2002
10-1233555-233-123
Error Log Entries and Test to Clear Values
Table 10-460. PI-LINK (Processor Interface Link) Error Log Entries
Error
Code
Aux
Data
Associated
Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test link <lnk-no> sh
1 (a) Any none MAJOR/
WARNING
2
2 Major and Minor alarms may be downgraded to Warning based on the value in set options.
OFF busyout/release link lnk-no
18 0 busyout link lnk-no WARNING OFF release link lnk-no
257 (b) Any none MINOR/
WARNING
2
OFF busyout/release link lnk-no
263 (c) Any none MAJOR/
WARNING
2
OFF busyout/release link lnk-no
513 (d) Any none MAJOR/
WARNING
2
OFF busyout/release link lnk-no
769 Any PI Loop Around
Test (#182)
WARNING ON test link lnk-no l r 2
1025 Any TDM Loop Around
Test (#183)
WARNING OFF test link lnk-no l r 2
1281 (n) Any none WARNING/
MAJOR
3
3 This error type initially raises a warning alarm. If it persists, and alarms are not downgraded on this
MO due to the values of set options, then a Major alarm is raised.
OFF test link lnk-no sh r 2
1537 (e) Any none WARNING/
MAJOR
3
OFF busyout/release link lnk-no
1793 (f) Any none WARNING OFF busyout/release link link no.
2049 (g) Any none WARNING/
MAJOR
3
OFF test link lnk-no sh r 9
2305 (h) Any none WARNING OFF test link lnk-no sh r 9
2561 (i) Any none WARNING/
MAJOR
OFF busyout/release link lnk-no
2817 (j) Any none NONE OFF busyout/release link lnk-no
3073 (k) Any none WARNING OFF test link lnk-no sh r 9
3585 (l) Any none MAJOR/
WARNING
2
OFF busyout/release link lnk-no
3841 (m) Any none MINOR/
WARNING
2
OFF busyout/release link lnk-no
Continued on next page