Table 10-469. PI-SCI System Communication Interface Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/
Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test interface PCS sh r 1
1 (a) 2055
2056
2057
2058
none none none none
257 (b) Any none MAJOR ON test interface PCS l
2
2 See WARNING below.
!
WARNING:
The test interface long command resets the PI-BD and causes all ISDN-PRI and
BX.25 links to come down.
769 (c) Any none MAJOR/
WARNING
3
3 Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
OFF test interface PCS l
2
1025 (d) Any none MAJOR/
WARNING
3
OFF test interface PCS l
2
1281 (e) Any Sci Start Test (#176) MAJOR/
WARNING
3
OFF test interface PCS l
2
1793 (f) Any none MAJOR ON test interface PCS l
2
2049 (g) 90xx Sci Start Test (#176) MAJOR ON test interface PCS l
2
2305 (f) Any Sci Self Test (#231) MAJOR ON test interface
PCS sh r 2
2561 (h) Any none MAJOR/
WARNING
3
OFF test interface PCS l
2
2817 (i) Any none MAJOR/
WARNING
3
OFF test interface PCS l
2
2818 (j) Any none MAJOR/
WARNING
3
OFF test interface PCS l
2
3073 (f) Any none MAJOR/
WARNING
3
OFF test interface PCS l
2

Table of Contents