PKT-CTRL (Packet Control Circuit Pack)
Issue 4 May 2002
10-1277555-233-123
k. If the specified Packet Control circuit pack is in the active SPE, it must first
be busied-out via the busyout packet-control C command. After testing
has been completed, the Packet Control circuit pack should be released
from the busyout state via the release packet-control C command.
System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system and deciding which ones to address, always
investigate errors in the order they are presented in the tables below. By clearing
error codes associated with the Packet Control Parity Circuitry Test, for example,
you may also clear errors generated from other tests in the testing sequence.
Table 10-477. Active PKT-CTRL
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive; ND = Nondestructive
Packet Control Reset Test (#586) D
Packet Control Parity Circuitry Test (#584) X ND
Packet Control Loop Around Test (#585) X X ND
Packet Control Error Counter Read and Clear
Test (#583)
XND
Table 10-478. Standby PKT-CTRL
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive; ND = Nondestructive
Packet Control Reset Test (#586) X X ND
Packet Control Loop Around Test (#585) X X ND
Packet Control Error Counter Read and Clear Test (#583) X X ND