Maintenance Object Repair Procedures
555-233-123
10-1296 Issue 4 May 2002
For the case where not all links are in the “Failed Links” category, examine
the alarm log and error log for failures of the following circuit pack types
and follow the repair procedures for those circuit packs before considering
replacing the TN2401/TN794 NetPkt associated with a suspect Packet
Interface:
■ Expansion Interface circuit pack (EXP-INTF)
■ ISDN-BRI Line circuit packs, ports, and stations (BRI-BD,
BRI-PORT, BRI-SET, ATT-PORT, ATT-ADJ, )
■ ISDN-BRI Trunk circuit pack and ports (TBRI-BD, TBRI-PT)
■ Universal DS1 circuit packs and ports (UDS1-BD, TIE-DS1)
■ DS1 Interface circuit packs and ports (DS1-BD, TIE-DS1)
■ C-LAN circuit packs and ports (CLAN-BD, RSCL-PT, PPP-PT,
ETH-PT)
■ ASAI circuit packs and ports (ASAI-BD, ASAI-PT, ASAI-ADJ,
ASAI-EPT, LGATE-BD, LGATE-PT, LGATE-AJ, ATTE-PT, ATTE-AJ,
MAPD-BD)
■ Media Processor circuit pack (MEDPRO, MEDPRO-RES)
Error Log Entries and Test to Clear Values
Table 10-483. Packet Interface Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/
Off
Board Test to Clear Value
1
0
2
0 Any Any ON test packet-interface 1CS r 2
1 (a) Any None MAJOR
3
ON reset io-processor
4
10 (b) 0 None
23 (c) 0 None MAJOR
3
OFF
50 (d) 0 None
100 (e) 0 None
217 (g) 0 None WARNING OFF
257 (f) Any None MAJOR
3
ON reset io-processor
4
267 (g) 0 None WARNING OFF
513 (h) Any None MAJOR
3
ON reset io-processor
4
769
5
(i) Any Mtce Looparound
Test (#886)
5
MAJOR
3
ON test packet-interface 1CS r 3
1025 (j) Any Private Looparound
Test (#885)
MAJOR
3
ON reset packet-interface 1CS
4
Continued on next page