Maintenance Object Repair Procedures
555-233-123
10-1370 Issue 4 May 2002
MTP Outpulse Relay Test (#102)
This test is a nondestructive test.When the internal modem is administered, the
test validates the correct operation of the remote access CO trunk used by
INADS. The MTP first goes off-hook, then on-hook on this trunk. If the loop current
is detected, the test passes. If the external modem is administered the MTP sends
an AT command sequence that will cause the external modem to go OFF-HOOK
and wait for dial-tone. If the modem detects dial-tone, the test passes. This test is
not allowed if the remote access line is in use.
1196 FAIL The MTP did not respond to being reset.
1. Retry at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit pack.
1197 FAIL The Maintenance Processor was reset, but it responded with a
NOT PASS status, indicating that it did not pass initialization
correctly. The MTP is not functioning correctly. The system
continues to function. Environmental monitoring is lost, as is
communication with the Standby Processor.
1. Retry at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.
NOTE:
If you replace the Processor circuit pack, you need to
obtain a new license file.
PASS The Maintenance Processor was reset, and it passed initialization
correctly. The other MTP tests should be examined to verify that
the MTP is functioning correctly.
1. Enter test processor a/b and verify that the MTP is
functioning correctly.
Table 10-506. TEST #101 MTP Reset Test Continued