Loading...
PR-MAINT (Maintenance Processor [TN2404/TN790
RISC Systems])
Issue 4 May 2002
10-1377555-233-123
2029 ABORT Internal system error
1. Retry at 1-minute intervals a maximum of 5 times.
FAIL The dual port RAM is not functioning correctly. Communication
between the processor and MTP is lost. The system is not able
to report environmental alarms, communicate with the Standby
SPE, or reboot from tape, if necessary.
1. Retry at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit
pack.
NOTE:
If you replace the Processor circuit pack, you need
to obtain a new license file.
PASS Dual port RAM is functioning. Communication exists between
the Processor circuit pack and the MTP.
Table 10-509. TEST #104 MTP Dual Port Ram Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page