Maintenance Object Repair Procedures
555-233-123
10-1380 Issue 4 May 2002
MTP Auxiliary Loop Around Test (#229)
This test is a nondestructive test. The test places the Auxiliary channel of the MTP
into a loop around mode, and it verifies the data integrity of the channel. The
Auxiliary channel is used as the CDR output port.
Table 10-512. TEST #229 MTP Auxiliary Loop Around Test
Error
Code
Tes t
Result Description/Recommendation
100 ABORT The test did not complete within the allowable time period.
1. Retry the command.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
1000 ABORT The system software resources required for this test are not
available.
1. Repeat the command at 1-minute intervals a maximum of 5
times.
1018 ABORT The test has been disabled via administration. The change
system-parameters cdr command needs to administer CDR.
(See the
Administrator’s Guide for Avaya MultiVantage
Software
for more information on administering this port.)
2000 ABORT Response to the test request was not received within the
allowable time period
2033 Internal system error
2034 Port busy
1. Repeat the command at 1-minute intervals a maximum of 5
times.
2500 ABORT The system software resources required for this test are not
available.
1. Retry at 1-minute intervals a maximum of 5 times.
Continued on next page