PR-MAINT (Maintenance Processor [TN2404/TN790
RISC Systems])
Issue 4 May 2002
10-1379555-233-123
MTP SAT Loop Around Test (#228)
This test is a nondestructive test. The test places the SAT channel of the MTP into
a loop around mode, and it verifies the data integrity of the channel. Although the
test is nondestructive, it causes loss of keyboard input from the PPN SAT.
Table 10-511. TEST #228 MTP SAT Loop Around Test
Error
Code
Tes t
Result Description/Recommendation
100 ABORT The test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System software resources required for this test are not
available.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to “STBY-SPE” for a description of these error codes.
2000 ABORT The response to the test request was not received within the
allowable time period.
2033
2034
ABORT Internal system error
Port busy
1. Retry at 1-minute intervals a maximum of 5 times.
FAIL The SAT channel failed the Loop Back Test. The SAT is
probably unusable for administration or maintenance. The
EPN SAT, if available, or remote access can still be used.
1. Retry at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit
pack.
NOTE:
If you replace the Processor circuit pack, you
need to obtain a new license file.
PASS The SAT channel passed the Loop Back Test.
1. If the PPN SAT is not usable, check the SAT itself, along
with the cabling.
Continued on next page