Maintenance Object Repair Procedures
555-233-123
10-1388 Issue 4 May 2002
MTP Reset Test (#101)
This test is destructive. The test resets the Maintenance/Tape Processor. The
destructive nature of this test causes the following:
Administration terminal to log off
CDR port to terminate data transmission
Any current tape access to terminate and also to tear down any remote
access INADS connection
Table 10-515. TEST #101 MTP Reset Test
Error
Code
Te s t
Result Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
10102 ABORT System software resources required for this test are not
available.
10104 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of
5 times.
10105 FAIL The MTP did not respond to being reset.
1. Retry the command at 1-minute intervals a maximum of
5 times.
2. If the test continues to fail, replace the Processor circuit
pack.