PR-MAINT (Maintenance Processor)
Issue 4 May 2002
10-1391555-233-123
10204 FAIL MTP reported test failure. No loop current detected.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, examine the INADS trunk for
connectivity, and manually check for loop current.
3. If there is no INADS trunk, this test should be disabled. To
disable the test, issue the change system-parameters
maintenance command, and change the Test Remote
Access Port field to n. If this test is failing on the Standby
SPE, issue the refresh spe-standby command, and rerun
the test.
4. If the INADS trunk checks out okay, but the test still fails,
check the backplane connector wiring.
5. If the backplane wiring checks out okay, replace the
Processor circuit pack at your earliest convenience.
PASS MTP detected a loop current on the remote access port.
1. If the system cannot call INADS, or INADS cannot contact
the system, check with the local Central Office for
problems with the INADS trunk, and verify that the INADS
number is correct.
10205 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
10206 ABORT System could not determine if the testing of the INADS port is
administered.
1. Enter the change system-parameters maintenance
command. Verify that the Test Remote Access Port? field
is set to y.
2. Retry the command at 1-minute intervals a maximum of 5
times.
10208 ABORT The remote access port is busy. INADS is probably dialed into
the switch.
1. If INADS is dialed in, the INADS trunk is working. There is
no need to run the test.
Table 10-516. TEST #102 MTP Outpulse Relay Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page