Maintenance Object Repair Procedures
555-233-123
10-1390 Issue 4 May 2002
Table 10-516. TEST #102 MTP Outpulse Relay Test
Error
Code
Te s t
Result Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
1018 ABORT The test has been disabled via administration.
1. To enable the test, issue the change system-parameters
maintenance command, and set the test remote access
port field to y. (If you have an INADS line, set the field to
y. If you are testing the Standby PR-MAINT, a refresh
spe-standby command must be successfully executed
before you proceed to Step 2.
2. Rerun the test.
1131 ABORT INADS port is busy because the system is reporting alarms to
INADS, or because INADS is dialed into the system.
1. Wait about ten minutes and then re-enter the command.
10201 ABORT System software resources required to run this test are not
available.
10202 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
10203 ABORT MTP did not respond to the test request.
1. Repeat the test at 1-minute intervals a maximum of 5
times.
2. If all MTP tests are aborting, execute the test processor
a/b long command in order to reset MTP and to examine
the results of the MTP Reset Test (#101).
3. Replace the Processor circuit pack.
4. If only the MTP outpulse relay test is aborting, escalate the
problem.
Continued on next page