Maintenance Object Repair Procedures
555-233-123
10-1398 Issue 4 May 2002
MTP Auxiliary Loop Around Test (#229)
This test is a nondestructive test. The test places the Auxiliary channel of the MTP
into a loop around mode, and it verifies the data integrity of the channel. The
Auxiliary channel is used as the CDR output port.
Table 10-521. TEST #229 MTP Auxiliary Loop Around Test
Error
Code
Tes t
Result Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
1000 ABORT The system software resources required for this test are not
available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1018 ABORT The test has been disabled via administration. The change
system-parameters cdr command needs to administer CDR.
2000 ABORT Response to the test request was not received within the
allowable time period.
2033
2034
ABORT Internal system error
Port busy
Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page