Memory Burst Read Test (#908)
This test verifies that the Memory Burst Read function works properly on the
Processor circuit pack.
Table 10-527. TEST #908 Memory Burst Read Test
Error
Code
Tes t
Result Description/Recommendation
100 ABORT The test did not complete within the allowable time period.
1. Retry the command.
1022
1335
2500
ABORT Internal system error
1. Retry the command.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
1 - 7 FAIL The Burst Read circuit is not functioning properly.
1. If the test fails, replace the Processor and retry the test.
(Note that if you replace the Processor circuit pack, you
need to obtain a new license file.)
PASS The Burst Read portion of the Processor circuit pack is operating
correctly.